 PI-41700 DC Bias Card 

 Specifications: tabs_spec.gif (3413 bytes)

Output Voltage: - 8.188 V to + 8.188 V
 Resolution:  4 mV
 Accuracy:  0.1% of programmed value ± 10 mV
Output Current:  ± 100 mA maximum

Current Limit: 

Three decade ranges:

 Range/Accuracy: 

100 mA - 3% of programmed value ± 3 mA
10 mA -- 3% of programmed value ± 300 µA
1 mA ---- 3% of programmed value ± 30 µA
Output Resistance:  75 milliohms for < IO = 100 mA
Output Noise: 

 

1 Hz                2.5  µV/rt.Hz
10 Hz              750 nV/rt.Hz
100 Hz            500 nV/rt.Hz
1 kHz              750 nV/rt.Hz
10 kHz            100 nV/rt.Hz
Voltage Sense:  0.2% of reading ± 5 mV
Current Sense: Three decade ranges:

 Range / Accuracy:

100 mA - 0.3% of reading ± 200 µA
10 mA -- 0.3% of reading ± 20 µA
1 mA ---- 0.3% of reading  ± 2 µA
Limit Indicator: 
Red LED limits or Disconnect indicator
Three decade ranges:

Range/Accuracy:  

100 mA - 3% of programmed value ± 7 mA
10 mA - 3% of programmed value ± 700 µA
1 mA - 3% of programmed value ± 70 µA

Voltage ADC Sense:

1 V to 8.188 V, Not specified below 1 volt

Accuracy:

1% ± 50 mV

Current ADC Sense:

Measurement Available - Not Specified

Power Consumption:

Pwr. Supply Min Typical Max
5.0 V ± 5% - 0.40 Amps -
3.3 V ± 5% - 0.50 Amps -
12 V ± 5% - 0.45 Amps -
-12 V ± 5% - 0.40 Amps -

Mechanical:

  • Size 6U Eurocard

  • Dimensions 6.30" x 9.18" (160.00mm x 233.35mm)

  • One card slot

Home  | 41700-General Info

 

 